NEMA 4X High Temperature Cabinet Coolers® Systems with Continuous Operation

High Temperature Cabinet Coolers for ambient temperatures of 125°F to 200°F (52°C to 93°C) are available in various cooling capacities for large and small control panels. Constructed of stainless steel, these NEMA 4X (IP66) Cabinet Coolers are ideal for food service and corrosive environments. The continuous operation systems are recommended for constant cooling and positive purge, including a Cabinet Cooler, cold air distribution kit, and filter. UL Listed and CE compliant, these coolers are a cost-effective and reliable way to cool and purge electronic control panels. Using a vortex tube to produce cold air from compressed air without moving parts, the compact Cabinet Cooler installs easily through a standard electrical knockout. The NEMA 4X (IP66) Cabinet Coolers, which are dust-tight, oil-tight, splash-resistant, and corrosion-resistant, feature a low-pressure relief valve that maintains the integrity of the enclosure by closing when not in operation.

Use our Cabinet Cooler Sizing Guide to submit information online about your control panel cooling problem.

For immediate help, call our Application Engineering Department at 080 - 31681897

How Cabinet Coolers Work

Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.

With or Without Thermostat Control

EXAIR Cabinet Coolers are available with or without thermostat control. Indeed, the choice between with or without thermostat control largely depends on the specific cooling needs and environmental conditions of your application.

Continuous Operation Coolers (Model 4200 and 4700 series): Ideal for applications requiring constant cooling and a continuous positive air purge.

Thermostatically Controlled Systems (Model 4300 and 4800 series): Efficiently manage cooling by activating only when internal temperatures near critical levels, saving air and energy. These systems are perfect where the heat load fluctuates and a continuous purge isn't necessary.

Moreover, every EXAIR Cabinet Cooler System comes with a 5 micron Automatic Drain Filter for clean compressed air and a Cold Air Distribution Kit to ensure effective air circulation within the enclosure.

Environmental Considerations

NEMA 12 (IP54) Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.

NEMA 4 (IP66) Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating, to maintain the integrity of a NEMA 4 enclosure.

NEMA 4X (IP66) Cabinet Coolers (corrosion resistant) offer the same protection as NEMA 4, but are constructed of stainless steel for food service, pharmaceutical and corrosive environments.

NEMA 4X (IP66) High Temperature Type 303/316 Stainless Steel Continuous Operation - Performance
Model Capacity Sound Level dBA
Btu/hr. Watts
HT4715SS, HT4715SS-316 1,000 293 73
HT4725SS, HT4725SS-316 1,700 498 80
HT4730SS, HT4730SS-316 2,000 586 80
HT4740SS, HT4740SS-316 2,800 821 82
HT4750SS, HT4750SS-316 3,400 997 84
HT4760SS, HT4760SS-316 4,000 1,171 84
HT4770SS, HT4770SS-316 4,800 1,406 84
HT4780SS, HT4780SS-316 5,600 1,641 85
Models HT4715SS, HT4715SS-316, HT4725SS, HT4725SS-316, HT4730SS, HT4730SS-316, HT4740SS, HT4740SS-316
NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 303 Stainless Steel, Continuous Operation
Model Btu/hr. (Watts)
HT4715SS 1,000 (293)
HT4725SS 1,700 (498)
HT4730SS 2,000 (586)
HT4740SS 2,800 (821)
HT4750SS 3,400 (997)
HT4760SS 4,000 (1,171)
HT4770SS 4,800 (1,406)
HT4780SS 5,600 (1,641)
NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 316 Stainless Steel, Continuous Operation
Model Btu/hr. (Watts)
HT4715SS-316 1,000 (293)
HT4725SS-316 1,700 (498)
HT4730SS-316 2,000 (586)
HT4740SS-316 2,800 (821)
HT4750SS-316 3,400 (997)
HT4760SS-316 4,000 (1,171)
HT4770SS-316 4,800 (1,406)
HT4780SS-316 5,600 (1,641)
  • Programmable controllers
  • Line control cabinets
  • Motor control centers
  • Relay panels
  • NC/CNC systems
  • Modular control centers
  • CCTV cameras
  • Computer cabinets
  • Cool laser housings
  • Electronic scales
  • Low cost
  • Compact
  • Cooling capacities up to 5,600 Btu/hr. (1,641 Watts)
  • Quiet
  • Install in minutes
  • Maintain NEMA 12 integrity (IP54)
  • Stabilize enclosure temperature and humidity
  • No CFC's
  • No moving parts - maintenance free
  • Mount in standard electrical knockout
  • Stop nuisance tripping
  • Stop heat damage
  • Eliminate fans and filters
  • Eliminate lost production
  • Stop circuit drift
  • Provide protection from dirt and dust

Office:

vps_logo

Vivek Pneutech Solutions Pvt. Ltd.

#22, 1st Floor, 1st Cross, Adj. to IIMB Compound, Bilekahalli Indl. Area, Bannerghatta Road, Bangalore, Karnataka,INDIA

Follow Us

Office

Image

Vivek Pneutech Solutions Pvt. Ltd.

#22, 1st Floor, 1st Cross, Adj. to IIMB Compound, Bilekahalli Indl. Area, Bannerghatta Road, Bangalore, Karnataka,INDIA

Follow Us

Image