NEMA 4 Hazardous Location Cabinet Cooler® Systems only

Hazardous Location NEMA 4 (IP66) Cabinet Coolers are designed for use in purged electrical enclosures within classified areas, including Class I Div 1, Groups A, B, C, and D; Class II Div 1, Groups E, F, and G; and Class III. Tested and approved by UL, these systems meet stringent UL requirements, making them a low-cost and reliable solution for cooling purged electric control panels. Available in cooling capacities from 1,000 Btu/Hr to 5,600 Btu/Hr, they can be quickly installed through a standard electrical knockout. These cabinet coolers, available in both thermostat-controlled and continuous operation models, are constructed to be dust-tight, oil-tight, splash-resistant, and corrosion-resistant, suitable for both indoor and outdoor service. They feature a low-pressure relief valve to maintain the integrity of the NEMA 4 enclosure when not in operation. Each system includes a water-dirt filter separator to prevent contaminants from entering your enclosure and a cold air distribution kit for targeted air circulation. All EXAIR HazLoc Cabinet Coolers are UL Classified and CE compliant. It's important to note that these coolers are not purged and pressurized control systems but are designed to be used in conjunction with one.

For immediate help, call our Application Engineering Department at 080 - 31681897

How HazLoc Cabinet Coolers Work

Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.

With or Without Thermostat Control

EXAIR Cabinet Coolers are available with or without thermostat control. Indeed, the choice between with or without thermostat control largely depends on the specific cooling needs and environmental conditions of your application.

Continuous Operation Coolers (Model 4200 and 4700 series): Ideal for applications requiring constant cooling and a continuous positive air purge.

Thermostatically Controlled Systems (Model 4300 and 4800 series): Efficiently manage cooling by activating only when internal temperatures near critical levels, saving air and energy. These systems are perfect where the heat load fluctuates and a continuous purge isn't necessary.

Moreover, every EXAIR Cabinet Cooler System comes with a 5 micron Automatic Drain Filter for clean compressed air and a Cold Air Distribution Kit to ensure effective air circulation within the enclosure.

Environmental Considerations

NEMA 12 (IP54) Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.

NEMA 4 (IP66) Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating, to maintain the integrity of a NEMA 4 enclosure.

NEMA 4X (IP66) Cabinet Coolers (corrosion resistant) offer the same protection as NEMA 4, but are constructed of stainless steel for food service, pharmaceutical and corrosive environments.

NEMA 4 (IP66) HazLoc Cabinet Cooler - Performance
Model Capacity Sound Level dBA
Btu/hr. Watts
HZ4615 1,000 293 73
HZ4625 1,700 498 80
HZ4630 2,000 586 80
HZ4640 2,800 821 82
Models HZ4615, HZ4625, HZ4630, HZ4640
NEMA 4 (IP66) HazLoc Cabinet Cooler
Model Btu/hr. (Watts)
HZ4615 1,000 (293)
HZ4625 1,700 (498)
HZ4630 2,000 (586)
HZ4640 2,800 (821)
  • Programmable controllers
  • Line control cabinets
  • Motor control centers
  • Relay panels
  • NC/CNC systems
  • Modular control centers
  • CCTV cameras
  • Computer cabinets
  • Cool laser housings
  • Electronic scales
  • Rated for Div I Hazardous Locations
  • UL Classified
  • Available in 8 different cooling capacities
  • No moving parts - maintenance free
  • Thermostat control reduces operating cost
  • Large cooling capacities up to 5,600 Btu/hr. (1,641 Watts)